LED Luminaire
-
PC 1x26 W BASIC
FL ballasts Electronic fixed output
- CELMA Energy Efficiency Index A2
- Nominal life-time up to 50,000 h (at ta 50 °C with a failure rate ≤ 0.2 % per 1,000 h
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life
- Temperature protection as per EN 61347-2-3 C5e
- Large temperature range
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC 1x18 T8 PRO lp
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC 1x36 T8 PRO lp
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC 1x58 T8 PRO lp
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC 2x58 T8 PRO lp
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC 3/4x18 T8 PRO lp
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC TC PRO 1/2x9 - 70w
FL ballasts Electronic fixed output
- CELMA Energy Efficiency Index A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.2% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Devices can operate either 1 or 2 lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Saftey shutdown of defective lamps and at end of lamp life (EOL 2)
- for emergency lighting systems as per EN 50172
- For luminaires with M and MM as per EN 60598, VDE 0710 and VDE 0711
- Temperature protection as per EN 61347-2-3 C5e
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
PC T5 PRO lp, PC TCL PRO lp, 14 -80 W
FL ballasts Electronic fixed output
- Highest possible CELMA Energy Efficiency Index EEI = A2 BAT
- Nominal life up to 100,000 h (at ta. 50 C with a failure rate max. 0.1% per 1,000 h)
- Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown)
- Precise lamp operation using adjustment of lamp parameters
- Advanced SMART-Heating for min. 50,000 starts without replacements of lamps
- Constant luminous flux irrespective of fluctuations in mains voltage
- Designed for THD < 10 %
- For luminaires of protection class I and protection class II
- Automatic start after replacement of defective lamps
- Safety shutdown of defective lamps and at end of lamp life (EOL 2)
- Insulation Displacement Connection (IDC) terminal for rapid automatic or manual wiring
- For emergency lightingsystems as per EN 50172
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock
-
EM BASIC, 230-240 V 50/60 Hz
Emergency lightingunits EM INVERTER
- Emergency lighting supply unit for manual testing
- For linear and compact fluorescent lamps
- Small dimensions (28 x 39 mm cross-section
- 1or 3 h rated duration
- Compatible with all eletronic ballasts (dimmable and non-dimmable)
- Can also be used in combination with conventional magnetic ballasts
- 5-pole technology: 4 lamp changeover and delayed power switching for the ballast
- Optimised AC output voltage for TC-DDand TC-L lamps
- Optimised DC output voltage for T8 lamps
- Cathode heating adapted for compact lamps
- Switchover relay with high-current contacts
- IDC (insulation displacement connection)
- Green charge status display LED
- Checking the emergency lighting function by interrupting the unswitched phase
- Deep discharge protection
- Battery connection, short-circuit protected (not reversible)
- No polarity reversal protection for battery
Regular Price: £110.00
Special Price Excl. VAT: £36.67 Incl. VAT: £44.00
Out of stock